APPLICATION: For automatic operation of a Pentair 3-way valve.
INSTALLATION:
- Remove Knob, Handle and four screws from the Valve Cover.
- Align splines of CVA-24 shaft over shaft of Valve.
- If CVA-24 is not aligned with mounting holes on Valve Cover, rotate CVA-24 (while still attached to Valve) until CVA-24 is positioned correctly over Valve.
- Use the 4 mounting screws provided to mount CVA-24 to Valve Cover.
- Mount Valve Handle and Knob to CVA-24.
- Connect cord into Power Center circuit board at appropriate Valve Actuator socket.
STAGING OF VALVE: If the Valve rotates to the wrong position (90 degrees out of phase), adjust the switch on the back of the CVA-24 between ON1 and ON2 position. This will rotate the Valve to the correct position.
SPECIFICATIONS:
Voltage: 24 VAC
Amps: 0.65
Torque: 250 inch pounds
Size: L 7.5", H 4.75", W 4.25"
Material: Housing - Noryl: Gears - steel
Grease: MoS2 Lubricant
Cord length: 15'
Rated: Outdoor use